A-1.4 Value Byte
Value Byte (VB)
Name
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
VB
Value
Value: Please refer to "Table - Host Request List" and "Table - Command Value List".
Table Command Value List
Value
Description
Input
The input that will be connected. (Port 1 = 1, Port 2 = 2… Port n = n)
0: Disconnect
Memory
Select Memory Location
0 : Current Status (Can‘t be stored)
Enable
1: Enable Status (example: Mute, Plug)
0: Disable Status (example: Un-mute, Unplug)
Level
Level Range (0 100)
0x81: Increase a step
0x82: Decrease a step
Delay
Audio delay time is 16-bit data. (Unit: 5ms or 10ms)
Delay1 - The audio delay time low byte. (Bit0 Bit7)
Delay2 - The audio delay time high byte. (Bit8 Bit15)
The audio delay time unit decided by the DTUF flag of the extend information.
The maximum Delay decided by the DTMAX flag of the extended information.
EDID
EDID Type
0: Fixed (Device default EDID)
1: Output 1 (Copy the EDID from the output 1)
-
Don’t care